Air Laser Particulate Matter Sensor - MPM11 series

MPM11 series laser dust sensor adopts laser scattering principle, with stable light source, constant light intensity, fast response, high detection accuracy and long service life.

  • Model Number: MPM11 series
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Air Laser Particulate Matter Sensor
Mouse over image to zoom

Product Specification

    MPM11 series laser dust sensor adopts laser scattering principle, with stable light source, constant light intensity, fast response, high detection accuracy and long service life.

 

Product parameters

Parameters

Indexes

Types of particle detection

PM1.0, PM2.5, PM10

Particle detection diameter range

0.3-10μm

Particulate matter concentration range

PM2.5 standard value

0~1000μg/m3

Particle Mass Concentration Resolution

1μg/m3

Consistency of particulate matter concentration(PM2.5 standard value) *Note

±10%(@100 ~ 500μg/m3)

±10μg/m3 (@ 0 ~100μg/m3)

Single response time

1s

Comprehensive response time

10s

DC supply voltage

5.0V

Working current

85mA

Stand-by current

45μA

Output method

UART / IIC / PWM

Storage temperature

-30~+70

Range of working temperature

-10~+60

Working humidity range

0-99%RH (without condensation)

Mean time between failures

3 Years

Dimensions

37 . 8*34 . 8*11.8mm(L×W×H)

Note: The particle concentration consistency data is data 2 in the communication protocol (test conditions: 25±2, 50±10%RH)

If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service