Infrared Gas Sensor for Oil Industry Methane Sensor - PrimePell
• Sensing ranges: 0-100% LEL Methane, 0-100% LEL Hydrocarbons or 0-100% Volume Methane
• Supply voltage range: 3.0V - 5.0V
• Power consumption: 280mW typical
• Zero repeatability: ± 1% of range
• Weight: 18.0 grams
• Relative humidity: 0 - 95% RH non-condensing
• Operating temperature range: -30°C to +50°C
• Operating pressure range: 700 - 1300 hPa
- Quantity:
- - +
Product Specification
PrimePell Oil Industry Infrared Methane Sensor Description and Operation
The PrimePell sensor uses the non-dispersive infrared method to detect the presence of hydrocarbon gases. The sensor contains an infrared radiation source, a dual element custom infrared detector, a unique optical waveguide into which gas diffuses and internal ARM7 core microprocessor based electronics to provide a voltage output which is independent of the power supply polarity. The sensors can be configured to provide a pellistor format output, typically mid supply at zero with the voltage output increasing with respect to the detector pin by 100mV at range, or a linear voltage output, typically 0.4V – 2.0V over range with respect to the negative supply pin. Inaddition, the output can be read and the internal configuration can be accessed by a serial communications link.The communication link contacts are pads in the 3 pin version PrimePell and pins in the 5 pin version PrimePell.The internal electronics perform all the functions of driving the optical parts of the sensor, extracting the detectorsignals, converting the signals to a concentration, applying temperature compensation and scaling the output.When in a pellistor configuration, the PrimePell can replace catalytic sensors in existing circuitry subject to thepower supply requirements. External components will be required to meet the power supply requirement when a PrimePell is used in constant current pellistor circuitry. The PrimePell is not currently Ex approved so should behoused in a suitable Ex enclosure when used in Hazardous areas.
PrimePell Oil Industry Infrared Methane Sensor Features
• Operates independent of supply polarity, as a pellistor
• Pellistor mimic Bridge output
• Voltage rises across detector connections in gas, as a pellistor
• Relative responses to key hydrocarbons are similar to a pellistor
• Operating voltage range 3.0V - 5.0V
• Operating current 80mA typical
• Latest technology MEMS detectors
• Sensing ranges: 0-100% LEL Methane, 0-100% LEL Hydrocarbons or 0-100% Volume Methane
• All metal construction with isolated housing
• Small internal volume
• Flexible electronic configuration access
• User calibration also enabled by hardware connections
• Wide operating temperature range
• Fast response
• Immunity from ‘poisoning’
PrimePell Oil Industry Infrared Methane Sensor Absolute Maximum Ratings
Ambient temperature range:
-40°C to +80°C
Supply voltage (measured between pins 2 and 3)
5.5V
PrimePell Oil Industry Infrared Methane Sensor Specification
Unless otherwise stated all data was taken using: Supply voltage of 3.5V. Ambient temperature (between 20°C and 25°C). Ambient pressure (between 995 hPa and 1020 hPa). Gases diluted in nitrogen. Gas Flowrate 1litre/min across sensor face.
Supply voltage range: |
3.0V - 5.0V |
Power consumption: |
280mW typical |
Default output range: Pellistor mode: Voltage mode: |
0 - 100mV from mid supply relative to detector pin 0.4V - 2.0V |
Warm up time: To operation To specification |
< 60s < 3 minutes |
Nominal ranges: |
0 - 100% LEL methane, 0 - 100% LEL hydrocarbons or 0 - 100% Volume methane |
Response time (T90) |
< 30s to a step change in gas concentration |
Minimum resolution: At zero At range |
< 0.5% of range <2% of range |
Zero repeatability: |
± 1% of range |
Accuracy: |
± 3% of range up to 50% of range ± 5% of range above 50% of range |
MTBF |
> 5 years |
Digital interface format: |
8 data bits, 1 stop bit, no parity |
Digital Interface Baud Rate: |
38400 (default), 19200, 9600 |
Digital Interface Logic Levels: |
VINL Input low voltage: <0.8V VINH Input high voltage: >2.0V VOL Output low voltage: <0.4V VOH Output high voltage: >2.4V |
Weight: |
18.0 grams |
Vibration: |
Complies with EN61779-1 |
Relative humidity: |
0 - 95% RH non-condensing |
Operating temperature range: |
-30°C to +50°C |
Storage temperature range: |
-40°C to +80°C |
Operating pressure range: |
700 - 1300 hPa |
If you cannot find what you want, you can entrust ISweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Ultra Low Power Digital Output NDIR CO2 Gas Sensor
-
Ultra Low Power Carbon Dioxide Sensor NDIR CO2 Sensor
-
Low Cost HVAC Carbon Dioxide Sensor NDIR CO2 Sensor
-
Probe Type NDIR CO2 Sensor
-
High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100%
-
High Resolution Infrared Methane (CH4) Sensor
-
Voltage Output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Voltage output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Fast Response NDIR CO2 Sensor Carbon Dioxide Sensor